Cup Mode

Cup Mode

1.  2-Cup - This will only grab the two cups off of the top of the stack. 
2. 32 Cup - This will run continuosly through the entire stack of cups
    • Related Articles

    • Adjusting cup sensors

      Take the colored cover off the top of the machine. Take the clear cover off in between the cup presser knobs. Insert cups into the loading tray (2-800 6-7000) cup sensors. Take a short Phillips head screwdriver and remove sensors.  Turn the sensor ...
    • Missing Cup on Fork Failure Cause

      If you are getting a "Missing Cup on Fork" failure cause, the most likely issues are simple fixes. First, confirm that the stack count is correct. If it is set to a different number than what is being put into the machine, it will cause this error. ...
    • Unpacking your iFill Cup master case

      Set your master case on a stable work surface, then carefully flip the case upside down.     With a box cutter, cut tape on all four side edges of the case.     Once cut, carefully reposition the box right side up and pull the box top up and off the ...
    • Stack Count Change

      If you would like to change the cup stack count or if your machine is not recognizing your current cup stack count, a stack count change is in order. Verify the number of cups in each individual stack in the machine. Press the "Stack Count" button. ...
    • Filling Issues

      What to do when you get channeling in the hopper or inconsistent fill volumes per pod: Ensure proper filling technique, slowly pouring the grounds in from left to right and right to left repeatedly. Ensure there is a hopper insert and that it is ...